AuthorFischer, Wilhelm. author
TitleCardiac Pacing in Clinical Practice [electronic resource] / by Wilhelm Fischer, Philippe Ritter
ImprintBerlin, Heidelberg : Springer Berlin Heidelberg : Imprint: Springer, 1998
Connect tohttp://dx.doi.org/10.1007/978-3-642-58810-5
Descript XX, 461 p. online resource

SUMMARY

Cardiac Pacing has undergone a rapid development in technique and application in recent years. This book aims to present fundamental knowledge about current findings in a concise and clear manner. Basic aspects are explained, such as defining indications, setting up diagnostic and therapeutic procedures, and caring for patients with specific focus on the most common questions patients ask of general practitioners. A vast amount of illustrative material is combined with very instructive text. This book addresses the daily practice of both internists and specialists in cardiology, while also serving as an excellent desk reference


CONTENT

Introduction: A Short History of Cardiac Pacing -- 1 Brief Review of the Anatomy, Electrophysiology and Pathophysiology of the Cardiac Conduction System -- 2 General Technical Concepts -- 3 The Pacing Modes -- 4 Indications for Permanent Pacing and Choice of Pacemaker -- 5 Implantation Techniques -- 6 Complications -- 7 Patient Follow-Up -- 8 Practical Guide to Programming -- 9 Pulse Generator and/or Lead Replacement -- 10 Conclusions -- General -- The Magnet Modes -- Medical Emergencies in Paced Patients -- Questions Asked by Paced Patients -- The Simple Questions -- Environmental Interference -- Appendix to Chapter 2 -- Additional Theoretical Notions of Electricity -- Additional Facts on Stimulating the Heart -- Appendix to Chapter 3 -- Special Non-Responsive SSI Mode Functions that Control the Escape Rate -- Bradycardia Diagnostic Functions -- Rate Smoothing -- Dynamic Overdrive -- Sleep Rate -- Special Non-Responsive DDD Mode Functions that Control the Escape Rate -- Automatic Search of Spontaneous QRS -- The Vitatron and Pacesetter Systems (AV Search Hysteresis, AVD Scanning) -- Automatic Switching from AAI to DDD; the ELA System -- Separate Programming of the Upper P Wave Synchronous Rate and of the Maximal Sensor Rate in DDDR Pacemakers -- The Maximal Sensor Rate (MSR) is Programmed Below the Upper P Wave Synchronous Rate (UR) -- The Maximal Sensor Rate Is Programmed at the Upper P Wave Synchronous Rate -- The Maximal Sensor Rate Is Programmed Above the Upper P Wave Synchronous Rate -- Protection Algorithms Against Atrial Arrhythmias -- Lower Rate Timing of the Pacemaker -- The European Pacemaker Cards and Codes 1998 -- Further Reading -- Sources of Figures -- Some Internet Addresses


SUBJECT

  1. Medicine
  2. Anesthesiology
  3. Cardiology
  4. Cardiac surgery
  5. Medicine & Public Health
  6. Cardiology
  7. Anesthesiology
  8. Cardiac Surgery